1、Manual Control Panel (machine set standard configuration) |
Provide set's basic start/stop
function, and has following basic configuration and function: |
·Start/stop controller |
·Three-phase AC ammeter |
·Voltmeter and selective switch |
·Frequency meter/ water thermometer/ oil pressure meter/ time meter/battery
voltmeter |
·Emergency stop button |
·Alarm functions: Over speed, high water temperature, low oil pressure,
fault of charge |
·Protective functions: They are low oil pressure; high water temperature;
over speed; emergency stop and other pre-setting protection. |
2、Non-electric Supply (Under-voltage) Self-start Control
Panel |
Besides the standard
manual control functions and configuration this control panel also
has: |
·Auto/stop/manual functions selection. |
·Start delay (3-5 s, adjustable). |
·Stop delay (0-270 s, adjustable). |
·three times self-start function. |
·Electric supply charger. |
·Alarm indication increase: Low/over speed, output voltage failure,
start fault, pre-alarm of high water temperature, emergency stop. |
·Protective function increase: Low/over speed, start failure, output
voltage failure (over voltage, under voltage, phase shortage). |
3、Full Automatic Remote Supervision Control Penal. |
·Liquid crystal display penal displays the running procedure, state,
failure and parameters of the generator set |
·Has RS232 or 485 interfaces and remote communication, remote testing
and remote supervision functions |
·Machine set protection, under the following situations it can stop
and alarm automatically: Start fault, over speed, under speed, high
water temperature, low oil pressure, speed sensor has not signal,
failure of charge, etc. |
4、Automatic Loading Switching Penal (ATS). |
·Four-pole mechanic, electric and compression air interlocking switching
switch |
·Electric supply, generating and loaded state indicating lamp. |
·Auto/manual selective dog |
·The penal body shall be treated through scouring, phosphorization
and spraying plastics |
·Has sufficient headspace for convenient installation of output
and input cable. |
·Auto-switching time is shorter than 7 s (adjustable). |
5、None Is on Duty, Independent Full Automatic Control
Penal |
·According to the user's need, we may provide the independent and
combinative control penal with both self-start control function
and automatic loading switching function. The operation of this
control penal is very convenient, and is very applicable to the
concentrative control of electrical equipment. |
6、Parallel Operation Control Penal |
·Manual/half automatic/full automatic two or multi-machine parallel
operation function. |
·Multi-machine parallel connection electric network, the power supply
is more reliable. |
·Concentrating dispatch, evenly distributing load, more convenient
maintenance and repair |
·More economical. The generator sets can be put into use according
to the actual load, so we can save oil. |
·The future extending is more elastic. The facilities can be increased
timely according to the need of development to meet the need of
load increasing. |
7、Heater |
·The diesel engine water temperature pre-heating system may provide
the start under cold and low temperature conditions. |
·The wet-proof system of generator may expel the condensate and
avoid frosting. |
8、Electric Supply Battery Charger. |
·Provide charge when the generator is in idle. |
9、Daily Fuel Box |
·The fuel in fuel box on the chassis can supply for 8 hours, the
bigger fuel box can be equipped at the outside of the generator
set. |
10、Strong Silencer. |
·In order to meet the requirements eliminating noise in environment
protection, the strong silencer can be equipped. The effect of this
two-circle erasure is better. |
11、Static Sound Shell. |
·This static sound shell can comply with the requirements of environment
protection in cities, and reduce the noise level to about 75 dB
(A). |
12、Mobile Shell |
·It is very convenient for the mobile power station in the field
construction. |
13、Spare Components and parts |
· According to the needs of users, we may supply the spare components